1Instruction ManualHI 83216Multiparameter BenchPhotometerfor Pool & Spa Applicationswww.hannainst.com
10INSTRUMENT DESCRIPTION1) Open Cuvette Lid2) Indexing mark3) Cuvette point4) Liquid Crystal Display (LCD)5) Splash proof keypad6) ON/OFF power switch
11KEYPAD DESCRIPTIONThe keypad contains 8 direct keys and 3 functional keys with the following functions:Press to perform the function displayed above
12(c) take out the syringe and clean the outside of the syringe tip. Be sure that no drops are hangingon the tip of the syringe, if so eliminate them.
13USING CUVETTES• Proper mixing is very important for reproducibility of the measurements. The right way of mixing acuvette is specified for each meth
14METHOD REFERENCE TABLEMethod Method Pagedescription1 Alkalinity 202 Calcium Hardness 223 Free Chlorine 25HEALTH & SAFETY• The chemicals containe
15POWER CONNECTION AND BATTERY MANAGEMENTThe meter can be powered from an AC/DC adapter (included) or from the built-in rechargeable battery.Note: Alw
16DATA MANAGEMENTThe instrument features a data log function to help you keep track of all your analysis. The data log canhold 200 individual measurem
17In the Setup mode the instrument’s parameters can be changed. Some parameters affect the measuringsequence and others are general parameters that ch
18Date / TimeThis option is used to set the instrument’s date and time.Press the Modify key to change the date/time.Press the W X functional keys to h
19HI 83216 offers an interactive contextual help mode that assists the user at any time.To access help screens press HELP.The instrument will display
2Dear Customer,Thank you for choosing a Hanna product. Please read this instruction manual carefully before using theinstrument. This manual will prov
20SPECIFICATIONSRange 0 to 500 mg/L (as CaCO3)Resolution 5 mg/LAccuracy ±5 mg/L ±10% of reading at 25 °CTypical EMC ±5 mg/LDeviationLight Source Tungs
21Alkalinity• Remove the cuvette.• Carefully add the content of one packet of HI 93755-0Alkalinity Indicator Reagent. Replace the cap and shakevigorou
22Calcium HardnessCALCIUM HARDNESSSPECIFICATIONSRange 0 to 500 mg/L (as CaCO3)Resolution 5 mg/LAccuracy ±10 mg/L ±5% of reading at 25 °CTypical EMC ±5
23Calcium Hardness• Add 1 drop of HI 93720C-0 EGTA solution to one cuvette (# 1), replacethe cap and invert the cuvette several times to mix. This is
24Note: This test will detect any calcium contamination in the beaker, measuring syringes or sample cells. Totest cleanliness, repeat the test multipl
25SPECIFICATIONSRange 0.00 to 5.00 mg/LResolution 0.01 mg/L from 0.00 to 2.50 mg/L;0.10 mg/L above 2.50 mg/LAccuracy ±0.03 mg/L ±3% of reading at 25 °
26• Press the Zero key. The meter will show “-0.0-” when the meter is zeroed and ready for measurement.• Remove the cuvette.• Add the content of one p
27Total ChlorineTOTAL CHLORINESPECIFICATIONSRange 0.00 to 5.00 mg/LResolution 0.01 mg/L from 0.00 to 2.50 mg/L;0.10 mg/L above 2.50 mg/LAccuracy
28Total Chlorine• Press the Zero key. The meter will show “-0.0-” when the meter is zeroed and ready for measurement.• Remove the cuvette.• Add 1 pack
29Cyanuric AcidCYANURIC ACIDSPECIFICATIONSRange 0 to 200 mg/LResolution 1 mg/L from 0 to 100 mg/L;10 mg/L above 100 mg/LAccuracy ±1 mg/L ±15% of readi
3PRELIMINARY EXAMINATIONPlease examine this product carefully. Make sure that the instrument is not damaged. If any damageoccurred during shipment, pl
30• Add the content of one packet of HI 93722-0 Cyanuric AcidReagent. Replace the cap and shake gently for about 10seconds (dissolution is not complet
31pHpHSPECIFICATIONSRange 6.5 to 8.5 pHResolution 0.1 pHAccuracy ±0.1 pH at 25 °CTypical EMC ±0.1 pHDeviationLight Source Tungsten lamp with narrow ba
32The instrument shows clear warning messages when erroneous conditions appear and when measured values areoutside the expected range. These messages
33The analyzed data can be managed using Hanna’s product HI92000, Windows® Compatible Software.DATA MANAGEMENTBattery Low: The battery capacity is low
34ACCESSORIESREAGENT SETSHI 93701-01 100 free chlorine tests (powder)HI 93701-03 300 free chlorine tests (powder)HI 93701-F 300 free chlorine tests (l
35WARRANTYAll Hanna Instruments meters are warranted for two years against defects in workmanship and materialswhen used for its intended purpose and
36Printed in EUROPE(ROMANIA)Hanna Instruments Inc.Highland Industrial Park584 Park East DriveWoonsocket, RI 02895 USATechnical Support for CustomersTe
4A major family leisure pursuit is the enjoyment of Swimming Pool and Spa facilities world-wide. A basic necessityof Pool water treatment, to ensure s
5THE WATER BALANCE AND LANGELIER INDEX (LI)The pool water characteristics need to be maintained in a balanced condition to avoid system failure. Measu
6Langelier Index (LI)The Langelier Index is a powerful tool to calculate the water balance, and to predict corrosion or scaling problems.Theoretically
7WATER INDEX REFERENCE TABLESEXAMPLE:Water Balance = pH + TF + HF + AF = 7.2 + 0.7 + 2.4 + 1.9 = 12.2Conclusion: the water is acceptable balanced but
8SPECIFICATIONSLight Life Life of the instrumentLight Detector Silicon PhotocellEnvironment 0 to 50°C (32 to 122°F);max 90% RH non-condensingPower Sup
9Where:-log I/Io= Absorbance (A)Io= intensity of incident light beamI = intensity of light beam after absorptionελ= molar extinction coefficient at wa