Hanna-instruments HI 4012 Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Instrumentos de medida Hanna-instruments HI 4012. Hanna Instruments HI 4012 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 16
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
1
HI 4012HI 4012
HI 4012HI 4012
HI 4012
HI 4112HI 4112
HI 4112HI 4112
HI 4112
Lead Ion
Selective Electrode
Instruction Manual
Half-cell
Combination
LEAD/SULFATE
HI 4012
HI 4112
LEAD/SULFATE
COMBINATION
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1 - Combination

1HI 4012HI 4012HI 4012HI 4012HI 4012HI 4112HI 4112HI 4112HI 4112HI 4112Lead IonSelective ElectrodeInstruction Manual Half-cell CombinationLEAD/S

Página 2 - +2 +2

10IX. IX. IX. IX. IX. Quick Check of Electrode SlopeQuick Check of Electrode SlopeQuick Check of Electrode SlopeQuick Check of Electrode Slo

Página 3 - . Lead sensors are “elec

11 applying gentle pressure. Continue polishing untilyou are satisfied with the surface. If dark depositsappear on polishing strip move the p

Página 4 - LEAD/SULFATE

12 Procedure1) Follow sections VIII and IX to prepare sensors formeasurement.2) Follow section VI to prepare standards / solution.Standards

Página 5

13This technique is called Known Addition. The method canuse an ideal sensor slope, but actual determined slopes atthe temperature of measurement sh

Página 6

14the sulfate ions forming a precipitate.Pb2+ + SO4.2- <—> PbSO4 (insoluble)At the stoichiometric end point, a change in mV occurs.Measuremen

Página 7

15Plot generated on Hanna HI 901 Titrator duringPlot generated on Hanna HI 901 Titrator duringPlot generated on Hanna HI 901 Titrator duringPlot ge

Página 8 - Deionized

16MAN4112 01/07 WARRANTY WARRANTY WARRANTY WARRANTY WARRANTYHanna Instruments Ion Selective Electrodes are warrante

Página 9 - COMBINATION

2HI 4012 Lead Half-cellHI 4012 Lead Half-cellHI 4012 Lead Half-cellHI 4012 Lead Half-cellHI 4012 Lead Half-cellHI 4112 Lead Combination Electrod

Página 10

3III. III. III. III. III. Theory of OperationTheory of OperationTheory of OperationTheory of OperationTheory of Operation:::::The HI 4012 or HI 4112 l

Página 11

4IV. IV. IV. IV. IV. Design elements of the HI 4012 and HI 4112Design elements of the HI 4012 and HI 4112Design elements of the HI 4012 and HI 41

Página 12

5V. V. V. V. V. Equipment required:Equipment required:Equipment required:Equipment required:Equipment required:• Hanna HI 5315 Double Junction Re

Página 13 - ISA=1 mL

6VIIVIIVIIVIIVII. General GuidelinesGeneral GuidelinesGeneral GuidelinesGeneral GuidelinesGeneral Guidelines• Use of a hood and protective clothing

Página 14

7• Gas bubbles may form from solution out-gassing dueto temperature change. Gently tap body of sensor todislodge them from sensing membrane.HI 4

Página 15

8VIII. VIII. VIII. VIII. VIII. Electrode PreparationElectrode PreparationElectrode PreparationElectrode PreparationElectrode PreparationHI 4

Página 16 - MAN4112 01/07

96. Holding the body of the electrode gently press uppercap with your thumb. This permits the fill solution todrain out of the body. Release cap and