Hanna-instruments HI 4007 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Instrumentos de medida Hanna-instruments HI 4007. Hanna Instruments HI 4007 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 16
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
1
HI 4007HI 4007
HI 4007HI 4007
HI 4007
HI 4107HI 4107
HI 4107HI 4107
HI 4107
Chloride Ion
Selective Electrode
Instruction Manual
CHLORIDE
HI 4007
HI 410
COMBINATION
7
CHLORIDE
Half-cell
Combination
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1 - Combination

1HI 4007HI 4007HI 4007HI 4007HI 4007HI 4107HI 4107HI 4107HI 4107HI 4107Chloride IonSelective ElectrodeInstruction ManualCHLORIDEHI 4007HI 410COMBINATI

Página 2

10IX. IX. IX. IX. IX. Quick Check of Electrode SlopeQuick Check of Electrode SlopeQuick Check of Electrode SlopeQuick Check of Electrode Slo

Página 3

11 If dark deposits appears on polishing strip move thepaper slightly and continue polishing.• If the sensor slope just misses the suggested slo

Página 4 - Membrane

12 Procedure1) Follow sections VIII and IX to prepare sensors formeasurement.2) Follow section VI to prepare standards/ solution. Stan-dar

Página 5

13XII. XII. XII. XII. XII. Other Measurement TOther Measurement TOther Measurement TOther Measurement TOther Measurement Techniquesechniquesechniquese

Página 6

14A chloride electrode may be used as an indicator to followthe progress of a chloride tiration with silver nitrate. Theelectrode can be used in colo

Página 7

15XV. XV. XV. XV. XV. Conversion tablesConversion tablesConversion tablesConversion tablesConversion tablesFor ClFor ClFor ClFor ClFor Cl-----Mul

Página 8 - Deionized

16MAN4107 05/08 WARRANTY WARRANTY WARRANTY WARRANTY WARRANTYHanna Instruments Ion Selective Electrodes are warrante

Página 9 - COMBINATION

2HI 4007 Chloride Half-cellHI 4007 Chloride Half-cellHI 4007 Chloride Half-cellHI 4007 Chloride Half-cellHI 4007 Chloride Half-cellHI 4107 Chloride Co

Página 10 - and place against damaged

3III. III. III. III. III. Theory of OperationTheory of OperationTheory of OperationTheory of OperationTheory of Operation:::::The HI 4007 or HI 4107 c

Página 11

4IV. IV. IV. IV. IV. Design elements of the HI 4007 and HI 4107Design elements of the HI 4007 and HI 4107Design elements of the HI 4007 and HI 41

Página 12 - 01234567

5V. Equipment required:V. Equipment required:V. Equipment required:V. Equipment required:V. Equipment required:• Hanna HI 5315 Double Junction Re

Página 13

6A user supplied oxidizing reagent may be used to supressinterferences such as hydroxide, sulfide, bromide, ammo-nia or cyanide . Add 10 mL to 100 mL

Página 14

7HI 4007• Remove protective cover from sensor tip.• Prepare HI 5315 reference electrode by filling electro-lyte reservoir with HI 7072 fill solution.•

Página 15

8VIII. VIII. VIII. VIII. VIII. Electrode PreparationElectrode PreparationElectrode PreparationElectrode PreparationElectrode PreparationHI 4

Página 16 - MAN4107 05/08

96. Holding the body of the electrode gently press uppercap with your thumb. This permits the fill solution todrain out of the body. Release cap and

Modelos relacionados HI 4107

Comentários a estes Manuais

Sem comentários