Hanna-instruments HI 9931 Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Instrumentos de medida Hanna-instruments HI 9931. Hanna Instruments HI 9931 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Instruction Manual
http://www.hannainst.com
These Instruments are in
Compliance with the CE Directives
A
L
A
R
M
L
IN
E
SET EC
0
S
E
C
O
N
D
S
m
S
1
.6
0
T
IM
E
R
M
IN
U
T
E
S
9
0
4
5
F
IN
E
S
L
O
P
E
C
A
L
C
O
A
R
S
E
P
R
O
P
O
R
T
IO
N
A
L
S
E
T
T
IN
G
S
A
L
A
R
M
AU
T
O
M
A
N
U
A
L
S
E
T
R
E
A
D
F
E
R
T.
S
E
T
P
O
IN
T
HI 9
1
2
.5
5
0
.8
mS
EC
F
E
E
D
EC
0
1
2
ALARM
m
A
O
U
T
P
U
T
4
/
2
0
0
/
2
0
mS
Z
E
R
O
C
A
L
HI 9931 - HI 9934
Wall Mounted
Conductivity & TDS
Controllers
Vista de página 0
1 2 3 4 5 6 ... 27 28

Resumo do Conteúdo

Página 1 - HI 9931 - HI 9934

Instruction Manualhttp://www.hannainst.comThese Instruments are inCompliance with the CE DirectivesALARMLINESET EC0SECONDSmS1.60TIMERMINUTES9045FINESL

Página 2 - TABLE OF CONTENTS

1021Open (NO) position.17. Powered dosage terminals (Relay)18. 110/115V or 220/240V power configuration19. Incoming power terminals20. FusesBOTTOM VIE

Página 3

11Specifications HI 9934RANGE 0.00 to 1999 ppm (mg/L)RESOLUTION 1 ppm (mg/L)ACCURACY ±2% F. S.(@20 C/68

Página 4 - MECHANICAL LAYOUTS

12GENERAL POINTS• The relay terminals relay terminals relay terminals relay terminals relay terminals of the controller are poweredpoweredpoweredpower

Página 5 - 221.8 mm

13SET ECALARMLINEBL DOSING PUMP0SECONDSmS1.60TIMERMINUTES9045FINECOARSEPROPORTIONAL SETTINGSALARMAUTOMANUALSETREADFERT.SET POINTHI 99311102.557.50.8mS

Página 6 - FUNCTIONAL DIAGRAM HI 9931

14• The contoller provides for automatic fail-safe secruityautomatic fail-safe secruityautomatic fail-safe secruityautomatic fail-safe secruityautomat

Página 7

15MAIN POWER SUPPLY CONNECTION•BeforeBeforeBeforeBeforeBefore connecting the unit to the mains connecting the unit to the mains connecting the unit

Página 8

16Make sure that the probe has been properly connected andwired to the controller (see preceding pages) and that themeter is plugged to the mains.Cali

Página 9 - FUNCTIONAL DIAGRAM HI 9934

17• Once the controller is calibrated to a solution by referring to itsvalue at 25 °C, all subsequent measurements are temperaturecompensated to 25 °C

Página 10 - BOTTOM VIEW

18PROPORTIONAL CONTROLPROPORTIONAL CONTROLPROPORTIONAL CONTROLPROPORTIONAL CONTROLPROPORTIONAL CONTROLIn order to optimize the controlling process and

Página 11

19e.g. HI 9934 proportional controlSetpoint = 1600 ppm TDS)Measured value = 1550 ppmDelta = 1600 - 1550 = 50 ppmProportional settings = ppm set to 200

Página 12 - CONNECTIONS & WIRING

2Dear Customer,Thank you for choosing a Hanna Product.Please read this instruction manual carefully before using the instru-ment. This manual will pro

Página 13 - ALARM CONNECTIONS

20OVERDOSAGE TIMEROVERDOSAGE TIMEROVERDOSAGE TIMEROVERDOSAGE TIMEROVERDOSAGE TIMERHI 9931 and HI 9934 provide for an overdosage alarm system. Theopera

Página 14 - TEMPERATURE COMPENSATION

21IMPORTANT: After performing the cleaning procedures rinse theprobe thoroughly with distilled or tap water. Dry it and replace thesleeve ensuring tha

Página 15 - 12401.20

22HI 7638 FOR IN-LINE INSTALLATIONHI 7638 comes with stainless steel 3/8” NPT external thread and60 mm (2.4”) immersion level. It can work at temperta

Página 16 - CALIBRATION

23EC/TDS PROBEHI 3001D 1/2” NPT platinum 20 mm (0.8”) long, 4-ring probewith temperature sensor and external threads forpipesHI 3002 1/2” NPT platinum

Página 18 - PROPORTIONAL CONTROL

25All Hanna controllers are warranted for two years against defectsin workmanship and materials when used for their intended purposeand maintained acc

Página 19

26• CABLES AND CONNECTORS• CALIBRATION AND MAINTENANCE SOLUTIONS• CHEMICAL TEST KITS• CHLORINE METERS• CONDUCTIVITY/TDS METERS• DISSOLVED OXYGEN METER

Página 20 - CLEANING PROCEDURE

27CE DECLARATION OF CONFORMITYCE DECLARATION OF CONFORMITYCE DECLARATION OF CONFORMITYCE DECLARATION OF CONFORMITYCE DECLARATION OF CONFORMITYDECLARAT

Página 21 - TROUBLESHOOTING

28MAN9931 10/99http://www.hannainst.comHANNA LITERATUREHANNA LITERATUREHANNA LITERATUREHANNA LITERATUREHANNA LITERATUREPRINTED IN PORTUGALHanna pub

Página 22 - HI 3002 FOR TANK INSTALLATION

3PRELIMINARY EXAMINATIONPRELIMINARY EXAMINATIONPRELIMINARY EXAMINATIONPRELIMINARY EXAMINATIONPRELIMINARY EXAMINATIONRemove the instrument from the pac

Página 23 - ACCESSORIES

4MECHANICAL LAYOUTSMECHANICAL LAYOUTSMECHANICAL LAYOUTSMECHANICAL LAYOUTSMECHANICAL LAYOUTSDIN connectorWIRING ACCESSPORTSEC012ALARMmA OUTPUT4/20 0/20

Página 24

53.8“96.9 mm25 mm1“75 mm3“Fig. 3227.8 mm9“188.6 mm7.4“221.8 mm8.7“174.8 mm6.9“Fig. 4Figure 3 is a dimensioned, bottom view of the wall mountedcontroll

Página 25 - WARRANTY

6FRONT PANELFUNCTIONAL DIAGRAM HI 9931FUNCTIONAL DIAGRAM HI 9931FUNCTIONAL DIAGRAM HI 9931FUNCTIONAL DIAGRAM HI 9931FUNCTIONAL DIAGRAM HI 9931EC012ALA

Página 26 - OTHER PRODUCTS FROM HANNA

7Unplug the instrument from the power supply beforewiring or replacing the fuses.2117. Powered dosage terminals (Relay)18. 110/115V or 220/240V power

Página 27 - CE DECLARATION OF CONFORMITY

8SETPOINT RANGE From 0 to 10.00 mS/cmSpecifications HI 9931RANGE 0.00 to 10.00 mS/cm (EC)RESOLUTION 0.01

Página 28 - PRINTED IN PORTUGAL

9FUNCTIONAL DIAGRAM HI 9934FUNCTIONAL DIAGRAM HI 9934FUNCTIONAL DIAGRAM HI 9934FUNCTIONAL DIAGRAM HI 9934FUNCTIONAL DIAGRAM HI 9934TDS0200400ALARMmA O

Modelos relacionados HI 9934

Comentários a estes Manuais

Sem comentários