Hanna Instruments Thermometer HI 7034 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Medição, teste e controlo Hanna Instruments Thermometer HI 7034. Hanna Instruments Thermometer HI 7034 User's Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 20
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
HI 8819 - HI 8820
Bench Conductivity
Meters
Instruction Manual
S
tandard C
onductivity at 25
°C
S
ta
ndard
H
I 7033
H
I 7031
H
I 7030
H
I 7034
C
onductivity
TEM
PERA
TURE
90 µS
1413 µS
12,880 µS
80,000 µS
O
F
F
O
N
S
tandard C
o
nductivity at 25
°C
S
tandard
H
I 70
33
H
I 7
031
H
I 7030
H
I 7
034
C
ondu
ctivity
TE
M
P
E
R
A
T
U
R
E
C
O
E
FF
IC
IE
N
T
9
0 µS
14
13
µS
12,880 µS
80,000 µS
O
FF
O
N
1
9
9
9
µS
1
9
9
.
9
µS
9
9
.9
m
S
1
9
.
9
9
m
S
0
0
.5
1
1
.5
2
2
.5
HI 8819
HI 8820
C
O
N
D
TEM
P
1999
µS
199.9
µS
99.9
mS
19.99
mS
http://www.hannainst.com
These Instruments are in
Compliance with the CE Directives
Vista de página 0
1 2 3 4 5 6 ... 19 20

Resumo do Conteúdo

Página 1 - Bench Conductivity

HI 8819 - HI 8820Bench ConductivityMetersInstruction ManualStandard Conductivity at 25°CStandardHI 7033HI 7031HI 7030HI 7034ConductivityTEMPERATURE90

Página 2 - TABLE OF CONTENTS

10• Press the COND/TEMP key to display conduc-tivity.• The display should read the conductivity of thecalibrating solution at the reference tempera-tu

Página 3

11CAL DC POWER12V to 20VCONDUCTIVITYELECTRODE+• Using a small screwdriver adjust the trimmer on the rear paneluntil the display shows the conductivit

Página 4 - KEYBOARD & REAR PANEL

12CONDUCTIVITY VERSUSCONDUCTIVITY VERSUSCONDUCTIVITY VERSUSCONDUCTIVITY VERSUSCONDUCTIVITY VERSUSTEMPERATURE CHARTTEMPERATURE CHARTTEMPERATURE

Página 5 - SPECIFICATIONS

13TEMPERATURE COMPENSATIONTEMPERATURE COMPENSATIONTEMPERATURE COMPENSATIONTEMPERATURE COMPENSATIONTEMPERATURE COMPENSATIONThe conductivity of an

Página 6 - TEMPERATURE

1421.510.50TEMPERATURE COEFFICIENTDETERMINATIONDETERMINATIONDETERMINATIONDETERMINATIONDETERMINATION OFOFOFOFOF THETHETHETHETHE TEMPERATURE

Página 7 - FOR HI8820:

15PROBE MAINTENANCEPROBE MAINTENANCEPROBE MAINTENANCEPROBE MAINTENANCEPROBE MAINTENANCERinse the probe with tap water afterevery series of measur

Página 8 - PROCEDURE FOR HI8819:

16ACCESSORIESACCESSORIESACCESSORIESACCESSORIESACCESSORIESCONDUCTIVITY BUFFER SOLUTIONS:HI 7030L 12880 µS/cm (µmho/cm), 460mLHI 7030M 12880 µS/cm (µm

Página 9 - TO CHECK THE CALIBRATION

17OTHER ACCESSORIES:CHECKTEMPC Electronic thermometer (range: -50.0 to 150.0°C)HI710005 Voltage adapter from 115VAC to 12VDCHI710006 Voltage adapter

Página 10 - PROCEDURE FOR HI8820:

18WARRANTYWARRANTYWARRANTYWARRANTYWARRANTYAll Hanna Instruments meters are guaranteed for two years againstdefects in workmanship and materials when u

Página 11 - ELECTRODE

19CE DECLARATION OF CONFORMITYCE DECLARATION OF CONFORMITYCE DECLARATION OF CONFORMITYCE DECLARATION OF CONFORMITYCE DECLARATION OF CON

Página 12

2Dear Customer,Thank you for choosing a Hanna Instruments Product.Please read this instruction manual carefully before using the instru-ment.This manu

Página 13 - TEMPERATURE COMPENSATION

MANBNCONR2 01/99http://www.hannainst.comPRINTED IN PORTUGAL

Página 14 - TEMPERATURE COEFFICIENT

3PRELIMINARY EXAMINATIONPRELIMINARY EXAMINATIONPRELIMINARY EXAMINATIONPRELIMINARY EXAMINATIONPRELIMINARY EXAMINATIONRemove the instrument from th

Página 15 - PROBE MAINTENANCE

4Standard Conductivity at 25°CStandardHI 7033HI 7031HI 7030HI 7034ConductivityTEMPERATURECOEFFICIENT84 µS1413 µS12,880 µS80,000 µSOFFON1999µS199.9µS99

Página 16 - CONDUCTIVITY PROBES:

5SPECIFICATIONSSPECIFICATIONSSPECIFICATIONSSPECIFICATIONSSPECIFICATIONSHI8819Range 0.0 to 199.9 µS/cm0 to 1999 µS/cm0.00 to 19.99 mS/cm0.0 to 99.9 mS/

Página 17 - OTHER ACCESSORIES:

6CONDUCTIVITY MEASUREMENTSCONDUCTIVITY MEASUREMENTSCONDUCTIVITY MEASUREMENTSCONDUCTIVITY MEASUREMENTSCONDUCTIVITY MEASUREMENTSMake sure that the

Página 18 - WARRANTY

721.510.50TEMPERATURE COEFFICIENTFOR HI8820:••••• Immerse the probe in the solution submergingthe holes of the sleeve (0.5 cm below). Tapthe probe li

Página 19

8CALIBRATIONCALIBRATIONCALIBRATIONCALIBRATIONCALIBRATIONINITIAL PREPARATIONIf you are measuring in the mS ranges, calibrate the meter usingHI7030 (or

Página 20 - PRINTED IN PORTUGAL

9CAL DC POWER12V to 20VCONDUCTIVITYELECTRODE+mSTEMPERATURE• Press the COND/TEMP key to display conduc-tivity readings and select the appropriateconduc

Comentários a estes Manuais

Sem comentários